IFM electronic MK5904 cylinder sensor with IO-Link; Reverse polarity protection yes; Overload protection yes; normally open / normally closed; (parameterisable); DC; PNP/NPN; 2 m PUR-Cable; IP 65; IP 67; Switching frequency 200 Hz
Code: MK5904Ordered item-
• Only 1 sensor for 2 end positions for short-stroke cylinders
• End position setting aid with second LED
• Inline quality monitoring with 50 mm detection range
• User-friendly communication and parameterization via IO-Link
• Monitoring of critical pneumatic cylinders via switching cycles counter
• Fast fault localization thanks to extensive diagnostic functions